Power supply
- Powersoft legendary universal switch-mode power supply up to 400VAC tolerant with Power Factor Correction
- Patented output filter with ripple cancellation network
- Low Inrush Limiting reduces AC inrush current, removing the need for expensive power sequencers
- Detachable AC mains cable with IEC C19/22.2 (16A for EU, 20 A for USA) socket
Protections
Fully protected circuit design with:
- Ac protection: shut down power supply when AC mains voltage is outside the operating range
- Clip limiter: prevents severely clipped waveforms from reaching loudspeakers, while still maintaining full peak power output
- DC protection: protects against infrasonic signal at the outputs
- VHF protections: protects the loudspeakers against non-audible, strong, non-musical high-frequency signals
- Short circuit protection: protects the amplifier from short circuit or other stressful events for the output circuits with automatic protection reset
- Long term limiter: protects the loudspeaker against steady long term RMS (non-audio) signals, by reducing maximum output
- Thermal protection: output stages operating temperature up to 80 °C (176 °F)
- Temperature controlled continuous variable speed fan, front to back airflow
- Temperature forecast with LCD traced historical behavior
General
- Fixed frequency switchmode output stage for high grade sound accuracy
- Compact size - all models only 1 RU for reduced rack cost and space
- Light weight - for easier racking and shipping: 7 kg (15.4 lbs)
- Standard Phoenix connectors: analog audio outputs, aux supply, alarms and GPIO
- Remotely switchable double input (main and aux) per channel
Loudspeaker system configuration
- Direct drive either low impedance loads or 70V / 100V Hi-Z distributed lines
- Switchable 35Hz / 70Hz high pass filter per channel
- Mixed configuration with Lo-Z/Hi-Z systems possible
- Bridged mode low impedance per channel pair
Alarms and GPI/O
- NC/NO contacts per channel for alarm notifications
- Remote ON/OFF switch
- Remote VCA control per channel
Remote Control & Monitoring
Via Software:
- Attenuation (from 0 dB to 26 dB)
- Max output voltage
- Output and gain reduction metering
- Diagnostics (temperature, fans, …)
Via Hardware:
- Attenuation (from 0 dB to 26 dB)
- High Pass Filter (35 Hz, 70 Hz)
- LoZ/HiZ/70V/100V output selection
- Gain (from 26 dB to 35 dB)
Specifications
GENERAL
Output power per Channel
Output power per Channel 1000 W @ 2 Ω 800 W @ 4 Ω 800 W @ 8 Ω
Bridge mode 2000 W @ 4 Ω 1600 W @ 8 Ω
Max output voltage / current
Max unclipped output voltage@8 Ω 115 Vpeak
Current 45 Apeak
AC MAIN POWER
Power supply Universal, regulated switch mode with PFC (Power Factor Correction)
Nominal power requirement 100-240 V ±10%, 50-60 Hz
Operating voltage 90 V – 264 V
Power consumption/Current Draw
Idle 115 V: 25.6 W – 0.38 A 230 V: 25.5 W – 0.23 A
1/8 of max output power @ 4 Ω 115 V: 270 W – 2.5 A 230 V: 276 W – 1.5 A
THERMAL
Operating temperature range 0° – 45° C – 32° – 113° F
Thermal dissipation*
Idle 115 V: 87 BTU/h 230 V: 87 BTU/h
1/8 of max output power @ 4 Ω 115 V: 238 BTU/h 230 V: 259 BTU/h